Perkins Generators

Perkins Generators

Our Product

Perkins Generator in Pakistan

OEM-grade engineering, tidy installations, and responsive after‑sales—Genesys supplies and supports Perkins diesel generators for homes, businesses, and industry across Pakistan, including Karachi, Lahore, and Islamabad.

Why Choose a Perkins Generator

Perkins engines are known for dependable starts, stable output, and broad parts availability—qualities that matter when outages cost real money. In mixed home and SME loads, they offer responsive torque for motor starts and smooth frequency control to protect sensitive electronics.

Stable

Quality AVRs and controller logic help maintain voltage and frequency within tight windows—reducing nuisance trips and protecting equipment.

Fuel‑aware Design

Engines achieve best efficiency around 60–80% load; we size and schedule accordingly so liters per kWh stay low.

Service Ecosystem

Perkins’ long presence in the region means spares, filters, and technical know‑how are readily available for timely service.

Serving major cities: We deliver and support Perkins generators in Karachi, Lahore, Islamabad, and nationwide—coordination handled from our Karachi head office.

Power Range & Popular Ratings

From compact standby sets for homes to larger three‑phase systems for workshops and clinics, we supply and integrate Perkins generators across common ratings. Use‑cases below are illustrative; we finalize sizing after a short load audit.

NoRatingTypical UsesNotes
1Perkins 20 kVAHomes, small clinics/shopsOften single‑phase; strong starts for essential appliances.
2Perkins 30 kVAHomes with multiple ACs; small officesBalanced output for mixed loads; quiet with a good canopy.
3Perkins 50 kVAWorkshops, mid‑size retail, labsThree‑phase; comfortable motor starting; ATS preferred.
4Perkins 100 kVAClinics, campuses, constructionParallel‑ready options for redundancy and growth.
Searching for “Perkins 20kVA generator price Pakistan” or “Perkins 100kVA generator price Pakistan”? Pricing varies by engine series, alternator class, canopy acoustics, controller features, and installation scope. Ask for an itemized quote to compare apples to apples.

Perkins Generator Price in Pakistan—What Really Drives Cost

We avoid vague per‑kVA numbers. Your proposal is itemized so you can see where money goes and what value you receive.

Cost Drivers

  1. Engine series and origin, alternator brand/class, and controller features.
  2. Silent canopy construction and rated dB(A) at 7 m; anti‑vibration mounts.
  3. ATS/AMF gear, breakers/contactors, protection, and sync capability.
  4. Installation scope: plinth, cabling, earthing, exhaust path, ventilation.
  5. Spare parts kits, tools, and maintenance plan.

What Our Quotes Include

Model numbers for engine, alternator, controller, and canopy acoustics.
Electrical SLD, layout, and cable schedules.
Delivery, installation, commissioning, operator training.
Optional monitoring and remote start wiring.

We also explain assumptions—duty cycle, ambient heat, and expected load range—so operating‑cost estimates stay realistic.

Perkins Generator Fuel Consumption per Hour—A Practical View

Fuel use depends on load, engine speed (e.g., 1500 RPM), ambient temperature, altitude, and maintenance condition. A sensible approach:
  1. Track load and liters per hour together; efficiency is best around 60–80% load.
  2. Keep filters clean and oil/coolant on schedule—poor service increases SFC.
  3. Avoid long low‑load idling to prevent wet‑stacking and deposits.
We estimate Perkins generator fuel consumption per hour after sizing your set—more reliable than generic tables.

Perkins Silent Generator with Canopy & ATS Panels

Acoustic Canopies

We specify lined panels, tuned air paths, and service access panels. When comparing “Perkins silent generator with canopy Pakistan,” check rated dB(A) at 7 m and airflow paths to avoid overheating or cleaning headaches

ATS & AMF

An ATS switches loads automatically during grid outages and back when power stabilizes. Quotes for “Perkins generator with ATS panel price Pakistan” vary by current rating, breaker/contactor, and enclosure grade.

Sizing & Selection (kW → kVA, Surges & Phases)

Correct sizing avoids fuel waste and extends engine life. Our checklist:If you’re comparing on grid solar system price in Pakistan or searching for grid tied solar packages Pakistan, focus on total value over 10–20 years—not just a headline per‑kW figure.
  1. Load audit: Running watts, surge currents, and simultaneity; sensitive loads noted.
  2. Duty cycle: Standby vs prime power, daily hours, seasonal peaks.
  3. kVA calculation: kVA ≈ kW ÷ Power Factor (PF often ~0.8 for mixed loads).
  4. Motor starts: Allow 2–6× running current for compressors/pumps; soft‑start or VFDs reduce surge.
  5. Phase & voltage: Single‑phase 230V vs three‑phase 400V; keep phases balanced.
  6. Derating: Apply for high ambient temps and altitude to protect lifespan.

Supply, Installation & Commissioning

Mechanical

  1. Plinth design for weight and vibration; anti‑vibration mounts.
  2. Exhaust routing with flexible couplings and clear discharge.
  3. Ventilation, service clearances, and weather protection.

Electrical

  1. Correct cable sizes and routes, earthing/bonding, labelled isolators.
  2. ATS logic, breaker curves, and protection that prevents backfeed.
  3. Commissioning load tests, controller setup, and operator training.

Handover includes SLD, layout, alarm list, maintenance schedule, and warranty cards. Early‑life checks validate trends after the first weeks of operation.

Perkins Generator Warranty and Service in Pakistan

We register warranties, maintain service logs, and schedule preventive visits. Spares—filters, belts, hoses, injectors, sensors—are planned based on your duty cycle.

Warranty & Support

  1. Manufacturer product/performance coverage per model.
  2. Installation workmanship coverage from our team.
  3. Early‑life inspections and priority fault response.

Spare Parts

We stock and source Perkins generator spare parts Pakistan with traceable serials—filters, sensors, AVRs, controllers—so downtime stays low.
Ask about UK‑origin engine options where applicable (Perkins engine generator UK origin Pakistan), subject to model and supply chain.

Used Perkins Generator for Sale in Pakistan—What to Check

When Used Makes Sense

  1. Lower annual hours and light‑to‑moderate loads.
  2. Documented service history and healthy compression.
  3. Clean output and stable AVR behavior under step loads.

Pre‑Purchase Checklist

  1. Run test at load; watch for smoke, vibration, or nuisance alarms.
  2. Inspect radiator, belts, hoses, mounts, and exhaust leaks.
  3. Verify phase balance and correct voltage/frequency.
We can perform pre‑purchase inspections and realistic refurbishment plans on request.

Perkins + Solar Hybrid—Cut Fuel Without Losing Uptime

Pair daytime solar with a Perkins generator for outages and peaks. We configure two‑wire start with hybrid inverters, prioritize solar generation, and keep the generator as a reliable safety net.

Explore Solar Solution Servicesrenewable hybrid solutions, and off‑grid designs to map the right blend for your site.

Homes, Commercial & Industrial

Homes

Quiet, tidy installs with ATS for seamless changeover. Essential vs non‑essential circuits reduce fuel burn and noise in neighborhoods.

  1. 20–30 kVA typical depending on ACs and surges.
  2. Clear owner guide for test runs and checks.

Commercial

Clinics, schools, retail, and offices demand predictable comfort and uptime. We plan phase balance, motor starts, and safe interlocks.

  1. 30–50 kVA common; quiet canopies recommended.
  2. Maintenance windows outside peak hours.

Industrial

Workshops and plants need robust mounting, fuel handling, and sometimes synchronization. We design for redundancy and growth.

  1. 50–100 kVA and above; parallel‑ready options.
  2. Planned spares and service kits for uptime.

Documentation, Quality Control & Handover

  1. Energy/load model, SLD, layout, earthing plan, cable schedules.
  2. Commissioning logs, controller settings, alarm list, and tests.
  3. Owner pack: maintenance schedule, spare part numbers, escalation contacts.

Representative Case Studies

Clinic — Perkins 30 kVA + ATS

Objective: seamless power for ACs and diagnostic equipment. Outcome: stable volt/freq under step loads, clear labelling, and trained staff for monthly tests.

Workshop — Perkins 50 kVA

Objective: start compressors and tools without dips. Outcome: correct cable sizing, phase balance, and a fuel plan that trimmed OPEX.

Villa — Perkins 20 kVA Silent

Objective: neighborhood‑friendly backup. Outcome: low noise and neat routing; owner later added solar for daytime savings.

Construction — Perkins 100 kVA Rental

Objective: prime power for site office and tools. Outcome: reliable runtime with logs and weekly service on‑site.

FAQs

Check engine series, alternator class, controller features, canopy acoustics, ATS/sync gear, installation scope, and after‑sales—then compare itemized quotes.

We supply and support Perkins sets across Pakistan with delivery and after‑sales coordinated from Karachi—serving Karachi, Lahore, Islamabad and more.

Yes, where neighbors or staff comfort matters. Evaluate rated dB(A) at 7 m, airflow path, and service access when you compare options.

Yes. ATS price depends on current rating, breaker/contactor type, controller features, and enclosure grade.

We estimate after sizing, based on your load profile and ambient assumptions. Operating near 60–80% load usually improves efficiency.

We stock/supply filters, belts, sensors, AVRs, and controllers with traceable serials—backed by service logs for warranty claims.

Where applicable and subject to model/supply chain. We’ll clarify engine/alternator origin in your quote.

We can source or inspect used sets. We recommend a load test, compression check, and AVR behavior review before purchase.

Genesys Generator GS-13

Perkins 403A-15G1 / 403D-15G

50Hz

12.5KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-14

Perkins 403A-15G1 / 403D-15G

50Hz

13 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-22

Perkins 404A-22G1 / 404D-22G

50Hz

20 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-33

Perkins 1103A-33G

50Hz

30 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-50

Perkins 1103A-33TG1

50Hz

45 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-65

Perkins 1103A-33TG2

50Hz

60 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-88

Perkins 1104A-44TG2

50Hz

80 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-110

Perkins 1104C-44TAG2

50Hz

100 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-165

Perkins 1106A-70TAG2

50Hz

150 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-220

Perkins 1106A-70TAG4

50Hz

200 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-275

Perkins 1506A-E88TAG3

50Hz

250 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-330

Perkins 1506A-E88TAG5

50Hz

300 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-385

Perkins 2206A-E13TAG2

50Hz

350 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-440

Perkins 2206A-E13TAG3 / 2206C-E13TAG3

50Hz

400 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-500

Perkins 2506A-E15TAG2

50Hz

500 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-650

Perkins 2806A-E18TAG2

50Hz

650 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-800

Perkins 4006-23TAG3A

50Hz

800 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-1000

Perkins 4008TAG2A

50Hz

1000 KVA (Prime)

4 Stroke

Download Now

Genesys Generator GS-1250

Perkins 4012-46TWG2A

50Hz

1250 KVA (Prime)

4 Stroke

Download Now

Contact Us

Our team and customer support 24/7 are available to serve you and to help you.

Head Office: MB-94 sector 6B Mehran Town, Korangi Industrial Area, Karachi, Pakistan​
Islamabad Office: Office #07, 2nd Floor, Segal Emporiums Murree Road, Saddar Cantt, Rawalpindi